99 research outputs found

    3D Simulation of Partial Discharge in High Voltage Power Networks

    Get PDF
    Open accessPartial discharge (PD) events arise inside power cables due to defects of cable’s insulation material, characterized by a lower electrical breakdown strength than the surrounding dielectric material. These electrical discharges cause signals to propagate along the cable, manifesting as noise phenomena. More significantly, they contribute to insulation degradation and can produce a disruptive effect with a consequent interruption of power network operation. PD events are, therefore, one of the best ‘early warning’ indicators of insulation degradation and, for this reason, the modeling and studying of such phenomena, together with the development of on-line PDs location methods, are important topics for network integrity assessment, and to define methods to improve the power networks’ Electricity Security. This paper presents a 3D model of PD events inside a void in epoxy-resin insulation cables for High Voltage (HV) power networks. The 3D model has been developed using the High Frequency (HF) Solver of CST Studio Suite® software. PD events of a few µs duration have been modelled and analyzed. The PD behavior has been investigated using varying electrical stress. A first study of the PD signal propagation in a power network is described

    Detecting Electromagnetic Disturbances on Transmission Lines Using Time Reversal

    Get PDF
    The file attached to this record is the author's final peer reviewed version.Transmission lines can suffer a variety of electromagnetic disturbances. These can range from intentional interference, due to malicious intent, through to the effects of lightning strikes or partial discharge. Given a high-fidelity model of the transmission line, it is possible to take measurement data and ‘run time backwards’ to identify the source of the disturbance. This paper reviews the theory and implementation of electromagnetic time reversal, provides some examples from the literature, and illustrates its operation with current research to identify the source of a partial discharge event on Medium and High Voltage cables

    Electromagnetic Time Reversal to Locate Partial Discharges in Power Networks with Inhomogeneous cables using the Transmission Line Matrix Method

    Get PDF
    This work was supported by the European Union’s Horizon 2020 Research and Innovation Programme under the Marie Skłodowska-Curie Grant under Agreement 838681.This paper describes a method for the on-line location of partial discharges (PD) in power networks based on the electromagnetic time reversal (EMTR) theory. PDs are localized electrical discharges that partially bridge the insulation between conductors and that start in cable insulation defects. Since the insulation degradation is often caused by PD, PD is regarded as a symptom of insulation degradation and on-line PD location is considered the most suitable monitoring method of network integrity assessment to prevent faults and improve network resilience. The proposed method, reversing in time the measured PD signals, refocuses them to their source allowing the location of PD site. The method uses the Transmission Line Matrix modelling approach to solve the backward propagation equations. In this paper, the effectiveness of the EMTR-based method to locate PDs in inhomogeneous power lines, using only one measurement point at a line end, is investigated and proved in simulation

    A new method to localize partial discharges on power cables using time reversal and TLM numerical method – A review

    Get PDF
    The file attached to this record is the author's final peer reviewed version.Insulation deterioration is often caused by partial discharge (PD) events. The adoption of on-line PD location methods is one of the most suitable methods to perform the power networks condition monitoring to improve their resilience and to guarantee electricity supply security. This paper reviews the results obtained in the design process of a new on-line PD location method based on the use of the electromagnetic time reversal (EMTR) theory and the Transmission Line Matrix (TLM) numerical method. Building on the work previously presented at the IWCS, where the method had been presented using two observation points, this paper shows further progress in this research and as a proof of its effectiveness, shows its ability in locating PDs using only one observation point. The procedure of the method is briefly described and its performance that overcomes the shortcomings of the traditional PD location methods are summarized. Finally, future related activities are described

    Time Reversal for Partial Discharge Localization on Power Lines with Different Termination Impedances

    Get PDF
    This paper describes a new method for the on-line location of partial discharges (PDs) in power transmission and distribution networks based on Electromagnetic Time Reversal (EMTR) theory and on the Transmission Line Matrix (TLM) method in order to describe the time reversed propagation. In particular, the paper shows the effectiveness of the method in localizing the PD source when the impedances at the terminations of the line are unknown and describes the procedure to be followed in this case. The analysis is performed in simulation, and a model of the PD signal propagation that is able to reproduce the distortion phenomenon that affect the PD signal propagation on power lines and thus the accuracy of the on-line PD location methods is also described

    Application to Real Power Networks of a Method to Locate Partial Discharges Based on Electromagnetic Time Reversal

    Get PDF
    This work was supported by the European Union’s Horizon 2020 Research and Innovation Programme under the Marie Skłodowska-Curie Grant under Agreement 838681.The paper presents an experimental validation of a method to locate partial discharges (PDs) on power distribution and transmission networks. The method is based on electromagnetic time reversal (EMTR) theory, and it uses a Transmission Line Matrix (TLM) model to describe the propagation of the PD signals in the reversed time. Since PDs are regarded as a symptom of insulation degradation, on-line PD location is considered an important approach to monitoring the integrity of a power distribution network, with the aim of detecting and preventing faults and improving network reliability. In this paper, the EMTR-based method is described and its effectiveness in PD localization using only one measurement point is demonstrated in three real 33 kV power lines. Its effectiveness is proved with and without an on-line electromagnetically noisy environment, and its accuracy is evaluated with respect to different signal-to-noise ratio (SNR) levels of the networks. The validation shows that the method is able to locate PDs with an error of 0.14% with respect to the total length of the line in the absence of noise, and with an error that is always lower than 0.5% for an SNR down to -7 dB

    Determination of Commercial Animal and Vegetable Milks’ Lipid Profile and Its Correlation with Cell Viability and Antioxidant Activity on Human Intestinal Caco-2 Cells

    Get PDF
    none9openantonella aresta; Stefania De Santis; Alessia Carocci; Alexia Barbarossa; Andrea Ragusa; Nicoletta De Vietro; Maria Lisa Clodoveo; Filomena Corbo; Carlo ZAMBONINAresta, Antonella; De Santis, Stefania; Carocci, Alessia; Barbarossa, Alexia; Ragusa, Andrea; De Vietro, Nicoletta; Lisa Clodoveo, Maria; Corbo, Filomena; Zambonin, Carl

    Involvement of GTA protein NC2β in Neuroblastoma pathogenesis suggests that it physiologically participates in the regulation of cell proliferation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The General Transcription Apparatus (GTA) comprises more than one hundred proteins, including RNA Polymerases, GTFs, TAFs, Mediator, and cofactors such as heterodimeric NC2. This complexity contrasts with the simple mechanical role that these proteins are believed to perform and suggests a still uncharacterized participation to important biological functions, such as the control of cell proliferation.</p> <p>Results</p> <p>To verify our hypothesis, we analyzed the involvement in Neuroblastoma (NB) pathogenesis of GTA genes localized at 1p, one of NB critical regions: through RT-PCR of fifty eight NB biopsies, we demonstrated the statistically significant reduction of the mRNA for NC2β (localized at 1p22.1) in 74% of samples (p = 0.0039). Transcripts from TAF13 and TAF12 (mapping at 1p13.3 and 1p35.3, respectively) were also reduced, whereas we didn't detect any quantitative alteration of the mRNAs from GTF2B and NC2α (localized at 1p22-p21 and 11q13.3, respectively). We confirmed these data by comparing tumour and constitutional DNA: most NB samples with diminished levels of NC2β mRNA had also genomic deletions at the corresponding locus.</p> <p>Conclusion</p> <p>Our data show that NC2β is specifically involved in NB pathogenesis and may be considered a new NB biomarker: accordingly, we suggest that NC2β, and possibly other GTA members, are physiologically involved in the control of cell proliferation. Finally, our studies unearth complex selective mechanisms within NB cells.</p

    Vaccination coverage in healthcare workers: a multicenter cross-sectional study in Italy

    Get PDF
    IntroductionIn recent years, a phenomenon known as "vaccine hesitancy" has spread throughout the world, even among health workers, determining a reduction in vaccination coverage (VC). A study aimed at evaluating VC among healthcare workers (HCWs) in 10 Italian cities (L'Aquila, Genoa, Milan, Palermo, Sassari, Catanzaro, Ferrara, Catania, Naples, Messina) was performed.Materials and methodsAnnex 3 of the Presidential Decree n. 445 of 28 December 2000 was used to collect information on the vaccination status of HCWs. The mean and standard deviation (SD) were calculated with regard to the quantitative variable (age), while absolute and relative frequencies were obtained for categorical data (sex, professional profile, working sector, vaccination status). The connection between VC and the categorical variables was evaluated by chi-square method (statistical significance at p&lt;0.05). The statistical analyses were performed by SPSS and Stata software.ResultsA total of 3,454 HCWs participated in the project: 1,236 males and 2,218 females. The sample comprised: physicians (26.9%), trainee physicians (16.1%), nurses (17.2%) and other professional categories (9.8%). Low VC was generally recorded. Higher VC was found with regard to polio, hepatitis B, tetanus and diphtheria, while coverage was very low for measles, mumps, rubella, pertussis, chickenpox and influenza (20-30%). ConclusionsThis study revealed low VC rates among HCWs for all the vaccinations. Measures to increase VC are therefore necessary in order to prevent HCWs from becoming a source of transmission of infections with high morbidity and/or mortality both within hospitals and outside

    Diagnosis, treatment and prevention of pediatric obesity: consensus position statement of the Italian Society for Pediatric Endocrinology and Diabetology and the Italian Society of Pediatrics

    Get PDF
    The Italian Consensus Position Statement on Diagnosis, Treatment and Prevention of Obesity in Children and Adolescents integrates and updates the previous guidelines to deliver an evidence based approach to the disease. The following areas were reviewed: (1) obesity definition and causes of secondary obesity; (2) physical and psychosocial comorbidities; (3) treatment and care settings; (4) prevention.The main novelties deriving from the Italian experience lie in the definition, screening of the cardiometabolic and hepatic risk factors and the endorsement of a staged approach to treatment. The evidence based efficacy of behavioral intervention versus pharmacological or surgical treatments is reported. Lastly, the prevention by promoting healthful diet, physical activity, sleep pattern, and environment is strongly recommended since the intrauterine phase
    • …
    corecore